Deskripsi Produk | Anaerobic Workstation (525L)- Anaerobic Bacteriology
- Offering the best condition for Culture of Anaerobic Microorganism
- O2 volume in chamber is kept on less 1%
- Sample condition are set automatically before sample is came into the Chamber by Air Lock Pass Box
- Less Gas Consumption Built in Natural Air Flow Incubator(Standard)
- Chamber(525Liter), Pass Box (27Liter)
- Available Glove-free Type ( Option )
Test condition can be set easily by PID Controller is focus on Customer's convenience and expediency, High Precision incubation is available by Auto-Tuning function. High efficiency test can be possible by trustworthy safety device.
![](https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjrKsfgJlCQsci244d6DcUsVq4OK3KsKHhuu63JCCEOCtB4zuhOeMx0kqvBNeXc5-0D3nsLWGtBzy3HmL9YsTNHVaF5AJTKGpIW__8FcvCVGuvPn8-eh2mvUeUZyZKvwlOJMU3opRIDG0wa/)
Feature for Anaerobic Workstation TRVS-5600A | | . There are included Incubator, Vacuum Pump, Catalyst and Drilite pack. | . The best condition on Vacuum Anaerobic test. | . This unit is the incubator for Tissue culture room of hospital, Laboratory and Food chemistry room and others to be cultured common germs (colon bacterium , Vacteria, etc..). Beside of germs culturing, this unit is used for storage test, environmental change test. | . Precision control is possible by DIGITAL PID CONTROLLER. | . Realization of anaerobic condition. | . Auto tuning function for high degree of precision | . There is included Natural convection type of incubator. | . Pass box for pollution prevention from outside. | . Recommendable Gas rate : Mix Gas(H2 5%, Co2 5%,N2 90%) , N2 Gas(99%) | | ※ Mix gas rate and using method are different depends on test purpose and method.
Specification Anaerobic Workstation | TRVS-5600A | Dimension (in) | 1,000 × 700 × 750(H)mm, 525Liter | Dimension (out) | 1,445 × 720 × 1,445(H)mm | Air Lock | 300 × 300 × 300(H)mm, 27Liter | Control | Programmable Logic Control Manual Control | Pressure Control | Automatic | Method | Positive Pressure, Hydrogen & Catalyst | Light Bank | F.L. 20W × 2EA | Standard Device | Vacuum Pump, Glove, Catalyst Pack, | Drilite Pack, Vacuum Gauge, | Manometer, Shelf, | Incubator, Petri Plate Rack | Power | 220V, 1.1KW, 50Hz | ※ Recommendable Gas Rate ( MIX GAS : H₂ 5%, CO₂ 5%, N₂ 90% / N₂ GAS : 99%) Internal Incubator | 5600-01 | Temp. Control | Digital PID Controller | Temp. Range | Ambient + 5℃ to 70 | Temp. Accuracy | ±0.2℃ at 37℃ | Display | LED Display | Door | 2 Door | Standard items Main Body, Internal Incubator, Petri Dish Plate Rack, Catalyst pack, Drilite pack, Glove, F.L Lamp,Manometer, Vacuum pump, Power Cable, Manual
|