Deskripsi Produk | Bio Hazard Safety Cabinet – Platinum Model Class Ⅱ Type B2In compliance with ISO 14644-1, ISO Class 3 (Class 10) standards ULPA Filter
- Stainless Steel chamber for excellent corrosion resistance and easy cleaning
- ISO 14644-1, ISO Class 4 (Class 10) standards compliance
- ULPA filter removes 99.999% of 0.3um particles.
- High Efficiency Dual Inlet is installed to provide reduced noise and vibration
- Temperaed safety glass sliding door is installed to protect users from UV exposure
- Dished work surface prevents spilled liquids not to overflow and allow easy cleaning and maintenance
Tempered Safety Glass Sliding Door
- With easy maintenance design, filters can be easily replaced
- Includes npt 1/4 air valve, gas valve, 110V or 220V electric socket (selectable), DPO test valve, UV lamps and FL lamps are installed as standard
- Maximum door opening alarm to protect the user and air flow performance
Pressure Gauge
- Pressure Gauge is installed as standard to check filter lifetime status
- Ratio of Exhausted Air.
- 100% of the air is exhausted.
- Microprocessor PID digital controller provides air velocity control
High Efficiency Dual inlet
- Air velocity and temperature monitoring
- Visual and audible alarms for low air velocity
- Alarm for filter using and replacement
Paper Catch
- UV lamp timer 99hr. 59min. available (Timer and alarm available)
- Setting value is preserved even when the power supply is cut
Safety: Broken temp. sensor error, over temperature protection, electric leakage circuit breaker
Microprocessor Digital Controller with LCD Display
Air Flow
Structure
Accessories
Specifications Model | LCB-903B-B2 | LCB-1203B-B2 | LCB-1503B-B2 | Dimensions Interior (WxDxH mm) Exterior | 890x620x635 1050x620x2050 | 1200x620x680 1350x800x1500 | 1500x620x680 1650x800x1500 | Air Volume Approx. | 980 m3/h | 1350 m3/h | 1700m3/h | Microprocessor Digital LCD Controller | Air velocity and Temperature monitoring, Automatic Air Velocity control Low Air Velocity visual & audible Alarm, Filter using & change time Alarm Clock and Timer, Auto stop for door excess open | HEPA Filter | Class 100, purity 0.3um Particle Removal 99.999% | Air flow Down flow velocity In flow | 0.3-0.36m/sec >0.5 m/sec 57³ /min | Noise Level | 56-60 dBA | Light | UV 20W x 1 EA, FL 20W x 1EA | UV 40W x 1 EA, FL 40W | UV 40W x 1 EA, FL 40W | Material Interior Exterior | Stainless steel grade 304 with hair lined finish Standard-Epoxy powder coated electro galvanized steel | Door | Tempered safety glass sliding door | Electrical Supply | 110 V 60 Hz or 220 V 50/60 Hz descrived order |
|