TR-GC1120 Main Machine
Lab Gas Chromatograph Machine with TCD, FID Detectors
Model: TR-GC1120 Series
GAS CHROMATOGRAPH | ||||||||
Model | TR-GC1120A | (GC+SPL+FID) | ||||||
Model | TR-GC1120B | (GC+SPL+PIP+2xFID) | ||||||
Model | TR-GC1120C | (GC+SPL+2xPIP+2xFID+Software) | ||||||
Specifications | ||||||||
Column oven Temperature range: Ambient temperature +7ºC-400ºC(increment 1ºC) Temperature control accuracy:better than +0.1ºC Temperature program ramps:5 ramps in total Program setting:0.1ºC-40ºC/min(increment 0.1ºC) Maximum run time:655minutes(increment 1min) | Hydrogen ionization detector(FID) Minimum detectable level:Dt<8x10-12g/s(n-hexadecane) Drift:<6x10-13A/h Liner dynamic range:>106 Maximum temperature:400oC | |||||||
Thermal conductivity detector(TCD) | Flame photometric detector(FPD) | |||||||
Nitrogen phosphorus detector(NPD) | Electron capture detector(ECD) |
Model# |
TR-GC1120 |
|
Description |
EPC |
|
Sample Introduction System |
Sample
injector and evaporation chamber |
|
Column Oven |
Temperature range |
Ambient
temperature +7℃ ~ 400℃ (in 1℃ increment) |
Temperature accuracy |
±
0.02℃ |
|
Cooling time |
400℃ to
50℃ in 6 min at 25℃
ambient |
|
Programmed temperature setting |
0.1℃~40℃/min
(in 1℃ increment) |
|
FID |
Detection limit |
≤3×10-12g/s
(C16) |
Drift |
≤6×10-13A/h |
|
TCD |
Sensitivity |
≥5000mV.mL/mg |
Baseline noise |
≤20µV |
|
FPD |
Detection limit |
≤8×10-13g/s(P)
; ≤8×10-11g/s(S) |
Drift |
≤2×10-11A/30min |
|
Baseline noise |
≤5×10-12A |
|
ECD |
Detection limit |
≤2×10-13g/s
(γ-666) |
Drift |
≤80µV/30min |
|
Baseline noise |
≤20µV |
|
Linear dynamic range |
≥103 |
|
NPD |
Detection limit |
≤5×10-13g/s(P)
; ≤5×10-12g/s(N) |
- Chromatography Type : Gas Chromatography
- Operation: PC Control
- Specification: ISO9002
- Chromatographic Column Type: Semi Preparative Column
- Temperature Range: 15-399
- Superior performance with advanced, microcomputer-based temperature control system;
- High temperature accuracy (optimum ± 0.02℃), high reliability, and anti-interference;
- Self-diagnosis/ self-protection function (overheat protection, power-off protection, etc.);
- Intuitive display of timing program, detector status, measurement range, current setting, etc.
Features:
- Column Compartment/oven with superior thermal performance, multistage (10 ramps) programmed temperature control function. (supported by “control system”);
- Advanced built-in data acquisition system , supporting real time instrument status monitoring, detection signal acquisition and PC control;
- Column oven accommodates up to 3 chromatographic columns, and supports quick heat-up and rapid cool-down with automated back-door opening. 450℃ to 50℃ in 6 min at 25℃ ambient);
- Flexible sample introduction system: 3 sample injectors could be installed and operated simultaneously with independent temperature control;
- High sensibility and stability detector;
- 2 independent and analog signals output;
- Clarity software, compatible with GLP/FDA-21 CFR Part11 requirements and regulations. (electronic records and signatures)
- Special analyzers, like RGA, NGA, PINDA, etc. according to ASTM standards;