GC-Gas Chromatograph-TR-GC1120

 

TR-GC1120 Main Machine

Lab Gas Chromatograph Machine with TCD, FID Detectors
Model: TR-GC1120 Series

GAS CHROMATOGRAPH
ModelTR-GC1120A  (GC+SPL+FID)
ModelTR-GC1120B  (GC+SPL+PIP+2xFID)
ModelTR-GC1120C  (GC+SPL+2xPIP+2xFID+Software)
Specifications
Column oven
Temperature range:
Ambient temperature +7ºC-400ºC(increment 1ºC)
Temperature control accuracy:better than +0.1ºC
Temperature program ramps:5 ramps in total
Program setting:0.1ºC-40ºC/min(increment 0.1ºC)
Maximum run time:655minutes(increment 1min)
 
Hydrogen ionization detector(FID)
Minimum detectable level:Dt<8x10-12g/s(n-hexadecane)
Drift:<6x10-13A/h
Liner dynamic range:>106
Maximum temperature:400oC
Thermal conductivity detector(TCD) Flame photometric detector(FPD)
Nitrogen phosphorus detector(NPD) Electron capture detector(ECD)



Model#

TR-GC1120

Description

EPC

Sample Introduction System

Sample injector and evaporation chamber

Column Oven

Temperature range

Ambient temperature +7 ~ 400 (in 1 increment)

Temperature accuracy

± 0.02

Cooling time

400 to 50 in 6 min at 25 ambient

Programmed temperature setting

0.1~40/min (in 1 increment)

FID

Detection limit

≤3×10-12g/s (C16)

Drift

≤6×10-13A/h

TCD

Sensitivity

≥5000mV.mL/mg

Baseline noise

≤20µV

FPD

Detection limit

≤8×10-13g/s(P) ; ≤8×10-11g/s(S)

Drift

≤2×10-11A/30min

Baseline noise

≤5×10-12A

ECD

Detection limit

≤2×10-13g/s (γ-666)

Drift

≤80µV/30min

Baseline noise

≤20µV

Linear dynamic range

≥103

NPD

Detection limit

≤5×10-13g/s(P) ; ≤5×10-12g/s(N)


  • Chromatography Type : Gas Chromatography
  • Operation: PC Control
  • Specification: ISO9002
  • Chromatographic Column Type: Semi Preparative Column
  • Temperature Range: 15-399
  1. Superior performance with advanced, microcomputer-based temperature control system;
  2. High temperature accuracy (optimum ± 0.02℃), high reliability, and anti-interference;
  3. Self-diagnosis/ self-protection function (overheat protection, power-off protection, etc.);
  4. Intuitive display of timing program, detector status, measurement range, current setting, etc.
Features:
  1. Column Compartment/oven with superior thermal performance, multistage (10 ramps) programmed temperature control function. (supported by “control system”);
  2. Advanced built-in data acquisition system , supporting real time instrument status monitoring, detection signal acquisition and PC control;
  3. Column oven accommodates up to 3 chromatographic columns, and supports quick heat-up and rapid cool-down with automated back-door opening. 450℃ to 50℃ in 6 min at 25℃ ambient);
  4. Flexible sample introduction system: 3 sample injectors could be installed and operated simultaneously with independent temperature control;
  5. High sensibility and stability detector;
  6. 2 independent and analog signals output;
  7. Clarity software, compatible with GLP/FDA-21 CFR Part11 requirements and regulations. (electronic records and signatures)
  8. Special analyzers, like RGA, NGA, PINDA, etc. according to ASTM standards;